Usually 1-2 Days (Next working day delivery may be possible) - 1pm cut-off
Shopping Basket
Your shopping basket is currently empty
Quote Request Basket
Your quote request basket is currently empty
Similar to the Yalelift 360 SR chain block, but with and integral geared (hand chain driven traverse) travel beam trolley as opposed to the standard hook suspension. The advantage of this built-in design rather then hooking the chain hoist in to the trolley suspension eye of a manual trolley, the hoists headroom (bearing point of wheels, to raised hook of the hoist unit) is reduced, allowing more versatility in low headroom applications where space is precious or restricted. There are 2 main disadvantages to the trolley being in-built, which are; the hoist and trolley must be handled and installed as a single piece, which means that the trolley-hoist combination would be heavier to install than a trolley alone, which the hoist could then be hooked in to afterwards. The second dissadvantage being that with an permanently fitted trolley, the hoist could not then be used for other applications, such as hooking in to beam clamps. If your preference is a seperate hoist and trolley, then the Yale HTP / HTG SR beam trolley will probably be of interest.
In nearly all industrial areas, there are workplaces which need to be protected against explosions. Because of the great damage an explosion could cause to people, property and materials, strict legal and technical requirements are imposed. The Spark Resistant range of chain hoists helps to make the workplace a safer environment.
All of Yale’s ATEX hoists meet the following standards: EN1127-1:1997; EN13463-1:2001; EN13463-5:2003, and are supplied complete with the relevant ATEX approval documentation.
Yale (Columbus McKinnon) offer three levels of protection - BASIC, MEDIUM, and HIGH.
Under directive 94/9/EC, equipment for areas with an explosion hazard are assigned to groups, categories and temperature classes. This is necessary as the requirements for equipment need not be the same for every application and for every hazard classification.
NB: It is the responsibility of the end user to identify the explosion proof classification required, NOT the hoist manufacturer or the supplier. Reference Directive 99/92/EC.
MEDIUM (Zone 1/21 & 2/22)
ATEX II 2 G Ex h IIB T4HIGH (Zone 1/21 & 2/22)
ATEX II 2 G Ex h IIC T4 Gb
ATEX II 2 D Ex h IIIC T135°C Db
Explosion protection for electrical and mechanical machinery is an important precautionary measure to ensure the safety of persons and all kinds of production, storage and distribution systems, when explosive mixtures of combustible gases, dusts and air may occur.
Explosion protection can mean to generally prevent the ignition of an explosive mixture. Explosion protection can also be achieved by eliminating potential ignition sources in advance, e.g. high temperatures and sparking. In many trades and industries, combustible gases, vapours and dusts are handled which have the potential to cause explosions.
| Model | YLIT ATEX 500 | YLIT ATEX 1000 | YLIT ATEX 2000 | YLIT ATEX 3000 | YLIT ATEX 5000 | YLIT ATEX 10000 |
| A min. (mm) | 245 | 272 | 323 | 382 | 550 | 784 |
| A1 (mm) | 158 | 178 | 205.5 | 252 | 260.5 | 380 |
| A2 (mm) | – | – | – | – | – | – |
| B (mm) | 17 | 22 | 30 | 38 | 45 | 68 |
| C (mm) | 24 | 29 | 35 | 40 | 47 | 68 |
| D (mm) | 14 | 19 | 22 | 30 | 37 | 50 |
| F (Geared trolley) (mm) | 92 | 92 | 91 | 107 | 149.5 | 113 |
| H1 (mm) | 24.5 | 24 | 23.5 | 32 | 30.5 | 55 |
| I (Push trolley) (mm) | 71.5 | 71.5 | 95.5 | 131 | 142.5 | 169 |
| I (Geared trolley) (mm) | 76.5 | 76.5 | 98 | 132.5 | 148.5 | 169 |
| L (mm) | 270 | 310 | 360 | 445 | 525 | 430 |
| L1 (mm) | 130 | 130 | 150 | 180 | 209 | 200 |
| L2 (mm) | 159 | 175 | 207 | 256 | 283 | 261 |
| M (mm) | M 18 | M 22 | M 27 | M 30 | M 42 | M 48 |
| O (mm) | 60 | 60 | 80 | 112 | 125 | 150 |
| P (Geared trolley) (mm) | 108 | 110 | 112 | 112 | 117 | 158 |
| T (Area A) (mm) | 280 | 290 | 305 | 320 | 364 | – |
| T (Area B) (mm) | 400 | 410 | 425 | 440 | 484 | 540 |
| No. of Chain Falls | 1 | 1 | 1 | 1 | 2 | 3 |
| Beam Flange Thickness Max. (mm) | 19 | 19 | 19 | 27 | 27 | 40 |
| Curve Radius Min. (m) | 0.9 | 0.9 | 1.15 | 1.5 | 2 | 1.8 |
| Weight @ 3m HOL (kg) Tpye ‘A’ Trolley | 24 | 32 | 49 | 82 | 130 | On Request |
Model Yalelift ITG ATEX, 500 - 3000 kg, single fall
Model Yalelift ITG ATEX, 5000 kg, double fall
Model Yalelift ITG ATEX, 10000 kg, three fall
If you wish to receive a quote for this product, please use the Pricing section to the right, this form is for general enquiries regarding this product only.
You can also request a quote through the pricing tab!
You can easily add more than one item to the Quote Request. This is highly recommended as we will be able to suit your needs much more efficiently.
Usually 1-2 Days (Next working day delivery may be possible) - 1pm cut-off
Similar to the Yalelift 360 SR chain block, but with and integral geared (hand chain driven traverse) travel beam trolley as opposed to the standard hook suspension. The advantage of this built-in design rather then hooking the chain hoist in to the trolley suspension eye of a manual trolley, the hoists headroom (bearing point of wheels, to raised hook of the hoist unit) is reduced, allowing more versatility in low headroom applications where space is precious or restricted. There are 2 main disadvantages to the trolley being in-built, which are; the hoist and trolley must be handled and installed as a single piece, which means that the trolley-hoist combination would be heavier to install than a trolley alone, which the hoist could then be hooked in to afterwards. The second dissadvantage being that with an permanently fitted trolley, the hoist could not then be used for other applications, such as hooking in to beam clamps. If your preference is a seperate hoist and trolley, then the Yale HTP / HTG SR beam trolley will probably be of interest.
In nearly all industrial areas, there are workplaces which need to be protected against explosions. Because of the great damage an explosion could cause to people, property and materials, strict legal and technical requirements are imposed. The Spark Resistant range of chain hoists helps to make the workplace a safer environment.
All of Yale’s ATEX hoists meet the following standards: EN1127-1:1997; EN13463-1:2001; EN13463-5:2003, and are supplied complete with the relevant ATEX approval documentation.
Yale (Columbus McKinnon) offer three levels of protection - BASIC, MEDIUM, and HIGH.
Under directive 94/9/EC, equipment for areas with an explosion hazard are assigned to groups, categories and temperature classes. This is necessary as the requirements for equipment need not be the same for every application and for every hazard classification.
NB: It is the responsibility of the end user to identify the explosion proof classification required, NOT the hoist manufacturer or the supplier. Reference Directive 99/92/EC.
MEDIUM (Zone 1/21 & 2/22)
ATEX II 2 G Ex h IIB T4HIGH (Zone 1/21 & 2/22)
ATEX II 2 G Ex h IIC T4 Gb
ATEX II 2 D Ex h IIIC T135°C Db
Explosion protection for electrical and mechanical machinery is an important precautionary measure to ensure the safety of persons and all kinds of production, storage and distribution systems, when explosive mixtures of combustible gases, dusts and air may occur.
Explosion protection can mean to generally prevent the ignition of an explosive mixture. Explosion protection can also be achieved by eliminating potential ignition sources in advance, e.g. high temperatures and sparking. In many trades and industries, combustible gases, vapours and dusts are handled which have the potential to cause explosions.
| Model | YLIT ATEX 500 | YLIT ATEX 1000 | YLIT ATEX 2000 | YLIT ATEX 3000 | YLIT ATEX 5000 | YLIT ATEX 10000 |
| A min. (mm) | 245 | 272 | 323 | 382 | 550 | 784 |
| A1 (mm) | 158 | 178 | 205.5 | 252 | 260.5 | 380 |
| A2 (mm) | – | – | – | – | – | – |
| B (mm) | 17 | 22 | 30 | 38 | 45 | 68 |
| C (mm) | 24 | 29 | 35 | 40 | 47 | 68 |
| D (mm) | 14 | 19 | 22 | 30 | 37 | 50 |
| F (Geared trolley) (mm) | 92 | 92 | 91 | 107 | 149.5 | 113 |
| H1 (mm) | 24.5 | 24 | 23.5 | 32 | 30.5 | 55 |
| I (Push trolley) (mm) | 71.5 | 71.5 | 95.5 | 131 | 142.5 | 169 |
| I (Geared trolley) (mm) | 76.5 | 76.5 | 98 | 132.5 | 148.5 | 169 |
| L (mm) | 270 | 310 | 360 | 445 | 525 | 430 |
| L1 (mm) | 130 | 130 | 150 | 180 | 209 | 200 |
| L2 (mm) | 159 | 175 | 207 | 256 | 283 | 261 |
| M (mm) | M 18 | M 22 | M 27 | M 30 | M 42 | M 48 |
| O (mm) | 60 | 60 | 80 | 112 | 125 | 150 |
| P (Geared trolley) (mm) | 108 | 110 | 112 | 112 | 117 | 158 |
| T (Area A) (mm) | 280 | 290 | 305 | 320 | 364 | – |
| T (Area B) (mm) | 400 | 410 | 425 | 440 | 484 | 540 |
| No. of Chain Falls | 1 | 1 | 1 | 1 | 2 | 3 |
| Beam Flange Thickness Max. (mm) | 19 | 19 | 19 | 27 | 27 | 40 |
| Curve Radius Min. (m) | 0.9 | 0.9 | 1.15 | 1.5 | 2 | 1.8 |
| Weight @ 3m HOL (kg) Tpye ‘A’ Trolley | 24 | 32 | 49 | 82 | 130 | On Request |
Model Yalelift ITG ATEX, 500 - 3000 kg, single fall
Model Yalelift ITG ATEX, 5000 kg, double fall
Model Yalelift ITG ATEX, 10000 kg, three fall
If you wish to receive a quote for this product, please use the tab, this form is for general enquiries regarding this product only.
You can also request a quote through the pricing tab!
You can easily add more than one item to the Quote Request. This is highly recommended as we will be able to suit your needs much more efficiently.
LiftingSafety uses cookies to improve your user experience.
Find out more