The Yalelift 360 SR Spark Resistant hand chain hoist once again proves its worth in an environment that far exceeds the requirements of a classical hand chain hoist. On the basis of the European Directive 2014/34/EU this model series has been further developed for the use in potentially explosive atmospheres (ATEX zones).
The 360° rotating hand chain guide allows the operator to work from almost any position, in confined spaces, above the load or at 90° to the load which makes it possible to use the hoist for horizontal pulling or tensioning. Due to the additional flexibility, the operator is no longer forced to work in the danger zone near the load.
Available in 500kg, 1000kg, 2000kg, 3000kg, 5000kg, 10000kg and 20000kg capacity options.
All of Yale’s ATEX hoists meet the following standards: EN1127-1:1997; EN13463-1:2001; EN13463-5:2003, and are supplied complete with the relevant ATEX approval documentation.
Yale (Columbus McKinnon) offer three levels of protection - BASIC, MEDIUM, and HIGH.
Under directive 94/9/EC, equipment for areas with an explosion hazard are assigned to groups, categories and temperature classes. This is necessary as the requirements for equipment need not be the same for every application and for every hazard classification.
NB: It is the responsibility of the end user to identify the explosion proof classification required, NOT the hoist manufacturer or the supplier. Reference Directive 99/92/EC.
MEDIUM (Zone 1/21 & 2/22)
ATEX II 2 G Ex h IIB T4
ATEX II 2 D Ex h IIIB T135°C Db
HIGH (Zone 1/21 & 2/22)
ATEX II 2 G Ex h IIC T4 Gb
ATEX II 2 D Ex h IIIC T135°C Db
Explosion protection for electrical and mechanical machinery is an important precautionary measure to ensure the safety of persons and all kinds of production, storage and distribution systems, when explosive mixtures of combustible gases, dusts and air may occur.
Explosion protection can mean to generally prevent the ignition of an explosive mixture. Explosion protection can also be achieved by eliminating potential ignition sources in advance, e.g. high temperatures and sparking. In many trades and industries, combustible gases, vapours and dusts are handled which have the potential to cause explosions.
The combination of the Yalelift 360 with a low headroom manual trolley provides even more flexibility in the application of the Yalelift 360.
| Model | YL 500 | YL 1000 | YL 2000 | YL 3000 | YL 5000 | YL 10000 | YL 20000 |
| A min. (mm) | 300 | 335 | 395 | 520 | 654 | 825 | 1010 |
| B (mm) | 17 | 22 | 30 | 38 | 45 | 68 | 85 |
| C (mm) | 24 | 29 | 35 | 40 | 47 | 68 | 64 |
| D (mm) | 133 | 156 | 182 | 220 | 220 | 220 | 303 |
| E (mm) | 148 | 175 | 203 | 250 | 250 | 383 | 555 |
| F (mm) | 148 | 167 | 194 | 219 | 219 | 219 | 250 |
| G (mm) | 139 | 164 | 192 | 225 | 242 | 326 | 391 |
| H (mm) | 206 | 242 | 283 | 335 | 352 | 436 | 501 |
| I (mm) | 24 | 24 | 31 | 34 | 21 | 136 | – |
| K (mm) | 61 | 70 | 83 | 95 | 95 | 95 | 396 |
| L (mm) | 87 | 97 | 111 | 124 | 124 | 124 | 125 |
| M (mm) | 110 | 125 | 156 | 178 | 285 | 401 | 471 |
| N (mm) | 14 | 19 | 22 | 30 | 37 | 50 | 56 |
| Number of Chain Falls | 1 | 1 | 1 | 1 | 2 | 3 | 6 |
| Chain Dimensions (mm) | 5 x 15 | 6 x 18 | 8 x 24 | 10 x 30 | 10 x 30 | 10 x 30 | 10 x 30 |
| Weight @ 3m HOL (kg) | 9 | 13 | 20 | 29 | 38 | 71 | 196 |
Model Yalelift 360 ATEX, 500 - 3000 kg, single fall
Model Yalelift 360 ATEX, 5000 kg, double fall
Model Yalelift 360 ATEX, 10000 kg, three fall
Model Yalelift 360 ATEX, 20000 kg, six fall
If you wish to receive a quote for this product, please use the Pricing section to the right, this form is for general enquiries regarding this product only.
You can also request a quote through the pricing tab!
You can easily add more than one item to the Quote Request. This is highly recommended as we will be able to suit your needs much more efficiently.
Usually 1-2 Days (Next working day delivery may be possible) - 1pm cut-off
The Yalelift 360 SR Spark Resistant hand chain hoist once again proves its worth in an environment that far exceeds the requirements of a classical hand chain hoist. On the basis of the European Directive 2014/34/EU this model series has been further developed for the use in potentially explosive atmospheres (ATEX zones).
The 360° rotating hand chain guide allows the operator to work from almost any position, in confined spaces, above the load or at 90° to the load which makes it possible to use the hoist for horizontal pulling or tensioning. Due to the additional flexibility, the operator is no longer forced to work in the danger zone near the load.
Available in 500kg, 1000kg, 2000kg, 3000kg, 5000kg, 10000kg and 20000kg capacity options.
All of Yale’s ATEX hoists meet the following standards: EN1127-1:1997; EN13463-1:2001; EN13463-5:2003, and are supplied complete with the relevant ATEX approval documentation.
Yale (Columbus McKinnon) offer three levels of protection - BASIC, MEDIUM, and HIGH.
Under directive 94/9/EC, equipment for areas with an explosion hazard are assigned to groups, categories and temperature classes. This is necessary as the requirements for equipment need not be the same for every application and for every hazard classification.
NB: It is the responsibility of the end user to identify the explosion proof classification required, NOT the hoist manufacturer or the supplier. Reference Directive 99/92/EC.
MEDIUM (Zone 1/21 & 2/22)
ATEX II 2 G Ex h IIB T4
ATEX II 2 D Ex h IIIB T135°C Db
HIGH (Zone 1/21 & 2/22)
ATEX II 2 G Ex h IIC T4 Gb
ATEX II 2 D Ex h IIIC T135°C Db
Explosion protection for electrical and mechanical machinery is an important precautionary measure to ensure the safety of persons and all kinds of production, storage and distribution systems, when explosive mixtures of combustible gases, dusts and air may occur.
Explosion protection can mean to generally prevent the ignition of an explosive mixture. Explosion protection can also be achieved by eliminating potential ignition sources in advance, e.g. high temperatures and sparking. In many trades and industries, combustible gases, vapours and dusts are handled which have the potential to cause explosions.
The combination of the Yalelift 360 with a low headroom manual trolley provides even more flexibility in the application of the Yalelift 360.
| Model | YL 500 | YL 1000 | YL 2000 | YL 3000 | YL 5000 | YL 10000 | YL 20000 |
| A min. (mm) | 300 | 335 | 395 | 520 | 654 | 825 | 1010 |
| B (mm) | 17 | 22 | 30 | 38 | 45 | 68 | 85 |
| C (mm) | 24 | 29 | 35 | 40 | 47 | 68 | 64 |
| D (mm) | 133 | 156 | 182 | 220 | 220 | 220 | 303 |
| E (mm) | 148 | 175 | 203 | 250 | 250 | 383 | 555 |
| F (mm) | 148 | 167 | 194 | 219 | 219 | 219 | 250 |
| G (mm) | 139 | 164 | 192 | 225 | 242 | 326 | 391 |
| H (mm) | 206 | 242 | 283 | 335 | 352 | 436 | 501 |
| I (mm) | 24 | 24 | 31 | 34 | 21 | 136 | – |
| K (mm) | 61 | 70 | 83 | 95 | 95 | 95 | 396 |
| L (mm) | 87 | 97 | 111 | 124 | 124 | 124 | 125 |
| M (mm) | 110 | 125 | 156 | 178 | 285 | 401 | 471 |
| N (mm) | 14 | 19 | 22 | 30 | 37 | 50 | 56 |
| Number of Chain Falls | 1 | 1 | 1 | 1 | 2 | 3 | 6 |
| Chain Dimensions (mm) | 5 x 15 | 6 x 18 | 8 x 24 | 10 x 30 | 10 x 30 | 10 x 30 | 10 x 30 |
| Weight @ 3m HOL (kg) | 9 | 13 | 20 | 29 | 38 | 71 | 196 |
Model Yalelift 360 ATEX, 500 - 3000 kg, single fall
Model Yalelift 360 ATEX, 5000 kg, double fall
Model Yalelift 360 ATEX, 10000 kg, three fall
Model Yalelift 360 ATEX, 20000 kg, six fall
If you wish to receive a quote for this product, please use the tab, this form is for general enquiries regarding this product only.
You can also request a quote through the pricing tab!
You can easily add more than one item to the Quote Request. This is highly recommended as we will be able to suit your needs much more efficiently.
LiftingSafety uses cookies to improve your user experience.
Find out more