| Model | Voltage | Lifting |
Net weight | Line speed max / min approx | Duty Cycle | Wire rope | Motor Type | Drum dimensions (mm) | ||||||||
| Capacity | Maximum lifting height (m) | Winch Only (kg) | Total Average Kit (kg) | First layer (m/min) | top layer (m/min) | (mm x m) | Safety Factor | Type | Output - Kilowatts | Output - Amperes | Length | Drum dia | Flange dia | |||
| 1173-13870 | 110v 1ph | 300kg | 43 | 42 | 44 | 12 | 18 | 25% with a max. of 60 starts per hour | 6 x 45 | Minimum 5:1 | - | 1.5kw | 20amp | 150 | 102 | 180 |
| 1173-13871 | 240v 1ph | 300kg | 43 | 42 | 44 | 12 | 18 | 6 x 45 | Minimum 5:1 | - | 1.5kw | 10.6amp | 150 | 102 | 180 | |
| 1173-13872 | 415v 3ph | 300kg | 29 | 32 | 34 | 10 | 15 | - | 5 x 30 | Minimum 5:1 | Induction motor | 0.75kw | 1.8amp | 110 | 94 | 154 |
* Mean drum diameter = the drum diameter plus the diameter of the wire rope
| Winch Dimensions (mm) | ||||||
| Model | A | B | C | D | E | Fixing holes |
| 1173-13870 / 1173-13871 | 156 | 197 | 300 | 252 | 624 | 4 off Ø 13.5 |

| Winch Dimensions (mm) | ||||||
| Model | A | B | C | D | E | Fixing holes |
| 1173-13872 | 142 | 142 | 241 | 210 | 548 | 6 off Ø 10.5 |

The minimum breaking force (MBF**) of the wire rope must be 5 x the lifting capacity of the hoist. The ratio of wire rope diameter to mean drum diameter* is usually at least 15:1. This will vary according to the application, the average operating time per day and the average and maximum weights being lifted.
As a general rule winches used in pulling applications rarely see their maximum rated capacity and are used intermittently for short running periods. In these applications the wire rope MBF** to winch rating can be a minimum 2:1 and the ratio of wire rope to mean drum ratio* as low as 10.1.
In applications where the winch is used for longer running times and more frequently sees higher loading conditions the wire rope to MBF** should be 3:1 and the ratio of wire rope to mean drum ratio* 12:1.
the permissible standard of wire rope MBF** to winch rating can be a minimum 2:1 and the ratio of wire rope to mean drum ratio* only 10:1. This minimum standard is permitted because the running time is so short and the winch rarely sees maximum load.
the maximum amount of wire rope on the drum must leave a freeboard to the top of the drum flange of 1.5 x wire rope diameter to prevent the wire rope coming off the drum.
If you wish to receive a quote for this product, please use the tab, this form is for general enquiries regarding this product only.
You can also request a quote through the pricing tab!
You can easily add more than one item to the Quote Request. This is highly recommended as we will be able to suit your needs much more efficiently.
| Model | Voltage | Lifting |
Net weight | Line speed max / min approx | Duty Cycle | Wire rope | Motor Type | Drum dimensions (mm) | ||||||||
| Capacity | Maximum lifting height (m) | Winch Only (kg) | Total Average Kit (kg) | First layer (m/min) | top layer (m/min) | (mm x m) | Safety Factor | Type | Output - Kilowatts | Output - Amperes | Length | Drum dia | Flange dia | |||
| 1173-13870 | 110v 1ph | 300kg | 43 | 42 | 44 | 12 | 18 | 25% with a max. of 60 starts per hour | 6 x 45 | Minimum 5:1 | - | 1.5kw | 20amp | 150 | 102 | 180 |
| 1173-13871 | 240v 1ph | 300kg | 43 | 42 | 44 | 12 | 18 | 6 x 45 | Minimum 5:1 | - | 1.5kw | 10.6amp | 150 | 102 | 180 | |
| 1173-13872 | 415v 3ph | 300kg | 29 | 32 | 34 | 10 | 15 | - | 5 x 30 | Minimum 5:1 | Induction motor | 0.75kw | 1.8amp | 110 | 94 | 154 |
* Mean drum diameter = the drum diameter plus the diameter of the wire rope
| Winch Dimensions (mm) | ||||||
| Model | A | B | C | D | E | Fixing holes |
| 1173-13870 / 1173-13871 | 156 | 197 | 300 | 252 | 624 | 4 off Ø 13.5 |

| Winch Dimensions (mm) | ||||||
| Model | A | B | C | D | E | Fixing holes |
| 1173-13872 | 142 | 142 | 241 | 210 | 548 | 6 off Ø 10.5 |

The minimum breaking force (MBF**) of the wire rope must be 5 x the lifting capacity of the hoist. The ratio of wire rope diameter to mean drum diameter* is usually at least 15:1. This will vary according to the application, the average operating time per day and the average and maximum weights being lifted.
As a general rule winches used in pulling applications rarely see their maximum rated capacity and are used intermittently for short running periods. In these applications the wire rope MBF** to winch rating can be a minimum 2:1 and the ratio of wire rope to mean drum ratio* as low as 10.1.
In applications where the winch is used for longer running times and more frequently sees higher loading conditions the wire rope to MBF** should be 3:1 and the ratio of wire rope to mean drum ratio* 12:1.
the permissible standard of wire rope MBF** to winch rating can be a minimum 2:1 and the ratio of wire rope to mean drum ratio* only 10:1. This minimum standard is permitted because the running time is so short and the winch rarely sees maximum load.
the maximum amount of wire rope on the drum must leave a freeboard to the top of the drum flange of 1.5 x wire rope diameter to prevent the wire rope coming off the drum.