Safe Working Load
Height Under Beam (mm)  @ £ 0.00
Reach (Arm Length) (7000 max) (mm)  @ £ 0.00
Hoist Options
Indoor / Outdoor
Fixing Options
Explosion Proof
Installation
Quantity
Unit Price : Quote Required
*** Recommended on higher value orders *** More information about shopping at SELS

MANUALLY ROTATED JIB CRANES

The manually rotated jib cranes are available for lifting capacities from 125 kg to 2000 kg and jibs from 2m to 8m. The Donati jib cranes are designed and manufactured according to the ISO A5 classification. The possible configuration are:
- GBA, floor mounted jib crane with square column characterized by a jib rotating angle of 300°.
The crane jib can be supplied in three different solution:
- "H" overbraced version, for lifting capacities from 125kg to 2000kg and outreach from 4m to 8m. The arm is made using a H-beam profile and the hoist-carrying trolley runs on its lower flange. The arm is fitted with one or two tie rods to support the profile which connect it to the rotation tube. This version allows the use of the jib crane for loads and outreach bigger than those possible with standard "C" and "T" solution. The arm allows the addition of either electric or hand-pushed trolley.

 

“H” overbraced version:

  • For lifting capacities from 125kg to 2000kg and jibs from 4m to 8m
  • The arm is made using a H-beam section, the hoist-carrying trolley run on the lower flange of the H-beam. The arm is fitted with one or two staybolts to support the profile which connects it to the rotation tube. This version allows the use of the jib crane for loads and jibs superior to those possible with the C and T versions.
  • The arm allows the addition of electrical and mechanical push-trolleys.Electrical Power SupplyThis is designed to power the hoist and/or electrical trolley, which run along the jib of the crane. It uses a connection box for the connection between the line and the power festoon cable, situated on the top of the column crane.
jib crane dimensions
Model Lifting Capacity Arm Size of jib Crane Total Height (H) Overall Dimensions Weight
Nominal Length (S) Under Beam (h) G M N T (IPE) Δ Crane Column by m
kg m m mm kg kg
H35C60 125kg 6 C 3.5 2738 310 180 890 160 17 278 34
H35C70 7 C 3.5 2738 310 180 950 160 17 298 34
H35D80 8 D 3.5 2738 310 180 1070 200 17 430 51
H35C40 250kg 4 C 3.5 2738 310 180 770 160 17 240 34
H35C50 5 C 3.5 2738 310 180 830 160 17 259 34
H35D60 6 D 3.5 2738 360 180 950 200 17 379 51
H35D70 7 D 3.5 2738 360 180 1010 200 17 405 51
H40E80 8 E 4 2980 415 180 1140 200 20 629 73
H35D40 500kg 4 D 3.5 2738 360 180 830 200 17 328 51
H35D50 5 D 3.5 2738 360 180 890 200 17 354 51
H40E60 6 E 4 2980 415 180 1020 200 20 568 73
H40E70 7 E 4 2980 415 180 1080 200 20 599 73
H40F80 8 F 4 2980 415 180 1220 240 20 812 100
H40E40 1000kg 4 E 4 2980 415 180 900 200 20 506 73
H40E50 5 E 4 2980 415 180 960 200 20 537 73
H40F60 6 F 4 2980 480 180 1100 240 20 735 100
H40F70 7 F 4 2980 480 180 1160 240 20 774 100
H40F40 2000kg 4 E 4 2980 480 220 1020 240 20 656 100
H40F50 5 E 4 2980 480 220 1080 240 20 695 100

Counter Plate Specifications

Size of Jib Crane A B C D E F
Counterplate Code
GBA5A0030 GBA5B0030 GBA5C0030 GBA5D0030 GBA5E0030 GBA5F0030
Measurements
C (mm) 600 600 900 900 1200 1200
S (mm) 20 20 30 30 40 40
x (mm) 260 260 410 410 370 370
y (mm) 180 180 260 260 380 380
Z (mm) - - - - 200 200
Ø (mm) 15 19 19 25 25 29
Counterplease Weight (kg)
56 56 191 191 452 452
Max. tiliting momentum allowed (kNm) (Mf)
9.98 15.4 29.13 53.39 103.59 158.58
Fixing Characteristics
Type of Concrete of the floor: class Rck min. (kg/cm2)
250 250 250 250 250 250
Type of chemical bolts
M12 M16 M16 M20 M20 M24
Min. thickness of the block of the floor (mm)
140 170 170 220 220 270
Dia. of the hole in the floor (mm) 14 18 18 24 24 28
Depth of the holein the concrete on the floor (mm) 110 125 125 170 170 210
Clamping couples of the anchors (Nm)
60 120 120 260 260 450
Min. resistance to traction on one anchor (kN)
9.6 13.6 16.5 26.5 27 37.9
Donati gba cbb cbe counter plates Donati gba cbb cbe counter plates Donati gba cbb cbe counter plates
Warning!
The fixing of the column using chemical bolts, needs a scrupulous check of suitability in relation to the type of support flooring. The suiability checks are the responsibility of the user and must be carried out by an expert, qualified technicians who will evaluate the feasibility and formally assume the relative responsibilities.

Base Plates

Note: The foundation frame with logbolts, used in the column-mounted version for fixing the column itself to the foundation plinth is supplied on request.

Base Plate Specifications

Size of Jib Crane A B C D E F
Base Plate and Foundation
C (mm) 190 220 270 320 380 450
P (mm) 280 310 390 440 550 620
S1 (mm) 20 20 25 25 30 30
S2 (mm) 8 8 10 10 12 12
x (mm) 240 268 337 388 471 540
y (mm) 100 111 140 161 195 224
Ø (mm) 260 290 365 420 510 585
r (mm) 70 71 86 95 136 137
Anchorage Bolts
Ø T (mm) M14 M14 M22 M22 M33 M33
LT (mm) 450 450 550 550 800 800
ST (mm) 40 40 55 55 75 75
Clamping Couples (Nm) 67 67 265 265 920 920
Foundation
Frame/bolts weight (kg) 7 8 20 21 60 62
Foundation plinth (L) 1200 1300 1400 1700 2000 2400
Foundation plinth (H) 800 800 900 900 1100 1100
Reaction (kN) Q1 3.3 5.7 10.15 18.4 28.7 29.35
Momentum (kNm) (MF) 5.7 10.16 18.9 35.86 69.92 115.1
Donati gba cbb cbe base plates Donati gba cbb cbe base plates Donati gba cbb cbe base plates
Warning!
The dimensions of the plinths are purely indicative! The plinth must be dimensioned by an expert, qualified technicians considering the real consistency of the grounded and the maximum pressure allowed by this.